  me10 10w-12w single output external power medical series www.slpower.com me10 rev 2.7 02-may-16 1 features ? meets ul/en/iec60601-1-2, 4th edition for emc * ? approved to en/iec/ul60601-1, 3rd edition applications with and isolation levels which satisfy the 2 mopp requirements ? meets doe efficiency level vi requirements ? no load input power ? average efficiency ? up to 12w of ac-dc power ? universal input 90-264vac input range ? desktop and wall-plug versions ? meets en55011/cispr11, fcc part 15.109 class b conducted & radiated emissions, with 6db margin ? e-cap life of >7 years ? <1,000,000 hours mtbf ? 3 year warranty ? ip22 rated enclosure description a high performance ac to dc external power supply family designed for medical applications. the me10 medical series external ac-dc power supplies are approved to safety en/iec/ul60601-1, 3rd edition, with isolation levels which satisfy the 2 mopp requirements; and designed to ul/en/iec60601-1-2, 4th edition for emc * . the me10 series models will operate at universal input range of 90 to 264vac over the wide temperature range of -20c to +50c, delivering full rated output power up to +40c and applicable output power derating at 50 c. these models are available in desktop and wall-plug versions, include an ip22 rating per iec60529 for the enclosure, and output cable terminated at a variety of output connectors. * consult factory for table 9 compliance information. model selection model output output ripple & line load output input number volts current power noise 1 regulation regulation connector configuration me10a0503f01 5.0v 2.0a 10w 75mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class i desktop, iec60320 c14 receptacle me10a0603f01 5.9v 1.6a 10w 75mv pk-pk 1% 5% me10a0703f01 7.5v 1.3a 10w 75mv pk-pk 1% 5% me10a0903f01 9.0v 1.1a 10w 90mv pk-pk 1% 5% me10a1203f01 12.0v 1.0a 12w 120mv pk-pk 1% 5% me10a1503f01 15.0v 0.8a 12w 150mv pk-pk 1% 5% me10a2403f01 24.0v 0.5a 12w 240mv pk-pk 1% 5% me10a0503n01 5.0v 2.0a 10w 75mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii desktop, iec60320 c8 receptacle me10a0603n01 5.9v 1.6a 10w 75mv pk-pk 1% 5% me10a0703n01 7.5v 1.3a 10w 75mv pk-pk 1% 5% me10a0903n01 9.0v 1.1a 10w 90mv pk-pk 1% 5% me10a1203n01 12.0v 1.0a 12w 120mv pk-pk 1% 5% me10a1503n01 15.0v 0.8a 12w 150mv pk-pk 1% 5% me10a2403n01 24.0v 0.5a 12w 240mv pk-pk 1% 5% me10a0503q01 5.0v 2.0a 10w 75mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii desktop, iec60320 c18 receptacle me10a0603q01 5.9v 1.6a 10w 75mv pk-pk 1% 5% me10a0703q01 7.5v 1.3a 10w 75mv pk-pk 1% 5% me10a0903q01 9.0v 1.1a 10w 90mv pk-pk 1% 5% me10a1203q01 12.0v 1.0a 12w 120mv pk-pk 1% 5% me10a1503q01 15.0v 0.8a 12w 150mv pk-pk 1% 5% me10a2403q01 24.0v 0.5a 12w 240mv pk-pk 1% 5% lps
me10 10w-12w single output external power medical series www.slpower.com me10 rev 2.7 02-may-16 2 model selection (continued) model output output ripple & line load output input number volts current power noise 1 regulation regulation connector configuration me10a0503b01 5.0v 2.0a 10w 75mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii wall-plug, interchangeable blades (north american blade included) 2 me10a0603b01 5.9v 1.6a 10w 75mv pk-pk 1% 5% me10a0703b01 7.5v 1.3a 10w 75mv pk-pk 1% 5% ME10A0903B01 9.0v 1.1a 10w 90mv pk-pk 1% 5% me10a1203b01 12.0v 1.0a 12w 120mv pk-pk 1% 5% me10a1503b01 15.0v 0.8a 12w 150mv pk-pk 1% 5% me10a2403b01 24.0v 0.5a 12w 240mv pk-pk 1% 5% me10a0503c01 5.0v 2.0a 10w 75mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii wall-plug, fixed north american blades3 me10a0603c01 5.9v 1.6a 10w 75mv pk-pk 1% 5% me10a0703c01 7.5v 1.3a 10w 75mv pk-pk 1% 5% me10a0903c01 9.0v 1.1a 10w 90mv pk-pk 1% 5% me10a1203c01 12.0v 1.0a 12w 120mv pk-pk 1% 5% me10a1503c01 15.0v 0.8a 12w 150mv pk-pk 1% 5% me10a2403c01 24.0v 0.5a 12w 240mv pk-pk 1% 5% notes: 1 . m e a s u r e d a t t h e o u t p u t c o n n e c t o r , w i t h n o i s e p r o b e d i r e c t l y a c r o s s o u t p u t a n d l o a d t e r m i n a t e d w i t h 0 . 1 f c e r a m i c a n d 1 0 f l o w e s r c a p a c i t o r s . f o r 5 v a n d 6 v m o d e l s , v a l u e s l i s t e d a r e t y p i c a l , 1 0 0 m v p k - p k m a x i m u m w i t h 0 . 1 f c e r a m i c a n d 4 7 f l o w e s r c a p a c i t o r s u s e d a t m e a s u r e m e n t p o i n t . 2. order blade kit kt-1027k for other blades (eu. uk, australia) 3. for eu fixed blades, replace ?c? in the model number with ?m?, for uk blades, replace ?c? with ?g?, for australia blades, replace ?c? with ?h?. 4. for input class i models: for ac gnd connected to output common (-), insert a ?b? in the part number where the ?a? is located (me10b0503f01). 5. all specifications are typical at nominal input, full load, at 25 c ambient unless noted. general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? turn on time less than 700ms @115vac, full load input current 115vac: 0.45a, 230vac: 0.22a hold-up time 20ms min., at full load, 100vac input inrush current 264vac, cold start: will not exceed 40a overtemperature protection will shutdown upon an overtemperature condition, auto-recovery. input fuses f1, f2: 3.15a, 250vac fuses (line & neutral lines) provided on all models overload protection 130 to 180% of rating, hiccup mode earth leakage current i n p u t - g n d : < 5 0 0 a @ 2 6 4 v a c , 6 0 h z , n c output-gnd: <4ma@264vac, 60hz, nc short circuit protection hiccup mode, auto recovery. efficiency >87%, typical overvoltage protection 130 to 150% of output voltage, hiccup mode output power 10 to 12w continuous ? see models chart for specific voltage model ratings. isolation input-output: 2 mopp input-ground: 1 mopp output-ground: 1500vac no load input power <0.1w per doe efficiency level vi requirements safety standards en/iec/ul60601-1, 3rd edition and en/iec/ul60601-1-11:2010 for home healthcare ripple and noise see models chart operating temperature -20c to +70c output voltage see models chart temperature derating see derating chart transient response 500 s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ? i/ ? t< 0.2a/ s. max. voltage deviation is +/-3.5%. storage temperature -40c to +85c regulation see models chart altitude operating: to 5000m. non-operating: -500 to 40,000 ft. drop test 1.4m from table top to wooden platform, 6 faces. relative humidity 5% to 95%, non-condensing vibration operating: 0.003g/hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500hz. non-oper.: random waveform, 3 minutes per axis, 3 axes and sine waveform, vib. frequency/acceleration: 10-500hz/1g, sweep rate of 1 octave / minutes, vibration time of 10 sweeps / axes, 3 axes shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine waveform, impact acceleration of 100g, pulse duration of 6 ms, number of shocks: 3 for each of the three axis e-cap life >10 year life based on calculations at 115vac/60hz & 230vac/50hz, ambient 25c at 24 hrs per day, 365 days/year, 6 power up cycles per day. mtbf >1,000,000 hours, full load, 110 & 220vac input, 25 c amb., per telcordia 332 issue 6, stress method.
me10 10w-12w single output external power medical series www.slpower.com me10 rev 2.7 02-may-16 3 emi/emc compliance conducted emissions: en55011/cispr11 class b, fcc part 15.107, class b: 6db margin typ, at 115 and 230vac radiated emissions: en55011/cispr11 class b, fcc part 15.109, class b: 3db margin typ, at 115 and 230vac common mode noise: high frequency (100khz-20mhz): <40ma pk-pk electro-static discharge (esd) immunity on power ports: en55024/iec61000-4-2, level 4: +/- 8kv contact, +/- 15kv air, criteria a iec60601-1-2, 4 th edition, table 4 radiated rf em fields susceptibility en55022/en61000-4-3, 10v/m, 80mhz-2.7ghz, 80% am at 1khz iec60601-1-2, 4 th edition, table 4 electrical fast transients (eft) /bursts: en55024/iec61000-4-4, level 4, +/- 4.4kv, 100khz rep rate, 40a, criteria a iec60601-1-2, 4 th edition, table 5 surges, line to line (diff mode) and line to gnd (cmn mode) en55024/iec61000-4-5, level 4, +/-2kv dm, +/-4kv cm, criteria a surpasses iec60601-1-2, 4 th edition requirements. conducted disturbances induced by rf fields en55022/iec61000-4-6, 3.6v/m ? level 4, 0.15 to 80mhz; and 12v/m) in ism and amateur radio bands between 0.15mhz and 80mhz, 80% am at 1khz iec60601-1-2, 4 th edition, table 5 rated power frequency magnetic fields en55024/iec1000-4-8, level 4: 30 a/m, 50/60 hz iec60601-1-2, 4th edition, table 4 voltage interruptions, dips, sags & surges en55024/iecen61000-4-11: --100% dip for 10 ms, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20ms, 0 deg., criteria a --100% dip for 5000ms (250/300 cycles), criteria b --60% dip for 100ms, criteria b --30% dip for 500ms, criteria a iec60601-1-2, 4th edition, table 5 harmonic current emissions en55011/en61000-3-2, class a flicker test en61000-3-3 all specifications are typical at nominal input, full load, at 25 c ambient unless noted. consult factory for information regarding testing for or usage under special environments. mechanical drawing iec60320 c14 receptacle, 2.5 x 5.5 x 9.5mm barrel connector interchangeable n.a. blade, 2.5 x 5.5 x 9.5mm barrel connector notes: 1. all dimensions in mm. 2. weight = 110g 2. interchangeable blade models come with north american blade fitted. for other blades (eu, uk, aust.) order blade kit kt1027k. 3. the unit should not be covered or enclosed to protect against excessive case temperature rise.
me10 10w-12w single output external power medical series www.slpower.com me10 rev 2.7 02-may-16 4 derating chart: connector information standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (ault #3), center positive. other standard options are listed below. the ?03? in the standard model number is replaced by the applicable digits below: data sheet ? 2016 sl power electronics corp. the information and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notice. 0 2 4 6 8 10 12 14 -20 -10 0 10 20 30 40 50 60 70 w a t t s a m b i e n t t e m p e r a t u r e ? c 5v 7v 12v 24v


▲Up To Search▲   

 
Price & Availability of ME10A0903B01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X